Place Gas Pressure Reducing Valve

To place a Gas Pressure Reducing Valve:

  1. In the Command Manager, select Pressure Reducing Valve from the Gas Devices Group.
  2. Click on the Place Feature Icon or double-click on the selected feature to start the placement command.

  3. Change the default property values as necessary in the Placement Form.

  4. Click at a location to place the Pressure Reducing Valve. If the Pressure Reducing Valve is placed on a Gas Main, a network connectivity relationship is automatically established and the device is oriented in the direction of flow reduction.
  5. Click at a location to place Annotation Text.
Note: The last step only occurs when attribute text is defined for the feature and auto-attribution is enabled. Additional steps are required when more than one attribute text is defined.